BLVVN - SYNTHOL SYMMETRO FLOW REDUCER, 8004
- MSDS: BLVVN
- Manufacturer: MARTIN SENOUR AUTOMOTIVE SALES
- Product Name: SYNTHOL SYMMETRO FLOW REDUCER, 8004
- National Stock Number: 8010-00N022582
Product Identification
Product ID:SYNTHOL SYMMETRO FLOW REDUCER, 8004
MSDS Date:02/08/1988
FSC:8010
NIIN:00N022582
MSDS Number: BLVVN
Responsible Party
COUNTRYSIDE, IL 60525
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: MART3
Contractor
Telephone: 216-566-2902
Cage: 16772
Ingredients
12
CAS: 64742-48-9
Fraction By Weight: 25%
OSHA PEL 300 PPM, 400 STEL
ACGIH TLV: 300 PPM
7.1
CAS: 100-41-4
RTECS: DA0700000
Fraction By Weight: <5%
OSHA PEL 100 PPM;125 PPM STEL
ACGIH TLV: 100 PPM;125 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.9
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 60%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SOLVENT NAPHTHA (PETROLEUM) LIGHT AROMATIC; (LIGHT AROMATIC
CAS: 64742-95-6
Fraction By Weight: 10%
ACGIH TLV: 100 PPM (MFR)
LABELING. DO NOT TAKE INTERNALLY. KEEP OUT OF
RTECS: 9999999ZZ
VAPOR AND SPRAY MIST. AVOID CONTACT WITH SKIN AND
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE)IRRIT OF EYES, SKIN & RESP
SYS.MAY CAUSE NERV SYS DEPRESS.EXTREME OVEREXP MAY RESULT IN UNCON
& POSSIBLY DEATH.(CHRONIC)PRLNGD OVEREXP TO SOLV INGREDS MAY CAUSE
ADVERSE EFTS TO LIVER, URINARY & REPRO SYS.RPTS HAVE ASSOC RPTD &
PRLNGD OVEREXP TO SOLV W/ PERM BRAIN & NERV SYS DMG.INTENTIONAL
MISUSE BY (SUPP DATA)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, AND LOSS OF
COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS AND
SPRAY MISTS. REDNESS AND ITCHING OR BURNING SENSATION MAY INDICATE
EYE OR EXCESSIVE SKIN EXPOS URE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE BREATHING.
KEEP WARM AND QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP
AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE RE- USE.
EYES : FLUSH WITH LARGE AMOUNTS OF WATER FORAT LEAST 15 MINUTES.
GET MD. INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
PERSON. DO NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. CALL
MD.
Fire Fighting
Flash Point Method:TCC
Flash Point:70.0F,21.1C
Lower Limits:0.7%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.WATER SPRAY MAY BE INEFT.IF WATER IS USED,FOG NOZZ ARE PREF. WATER
MAY BE USED TO COOL CLSD (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD.ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME.CLSD CNTNRS MAY EXPLODE WHEN
EXPSD TO EXTREME HEAT.APPLICATN TO HOT SURF (SUPP DATA)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CONTENTS ARE FLAM.KEEP AWAY FROM HEAT,
SPARKS & OPEN FLAME.CONSULT NFPA CODE.USE APPRVD BONDING & GROUDING
PROC. KEEP CNTNR CLSD WHEN NOT IN USE.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
VENT,DO NOT SMOKE, EXTING ALL FLAMES, PILOT LIGHTS & HEATERS, TURN
OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
IGNIT.TRANSFER ONLY TO APPR VD CNTNRS W/COMPLETE & APPROP(SEE ING
5)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED NIOSH/MSHA
APPROVED ORGANIC VAPOR/PARTICULATE RESPIRATOR FOR PROTECTION
AGAINST MATERIALS IN IN GREDIENT SECTION.
Ventilation:LOCAL EXHST PREF. GENERAL EXHST ACCEP IF EXPOSURE TO MATLS
IN INGRED SECTION IS MAINTAINED
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: CNTNRS TO PVNT PRESS BUILD- UP & POSS AUTOIGNIT/EXPLO
WHEN EXPSD TO EXTREME HEAT. EXPLO HAZ: REQ SPECIAL PREC. DURING
EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMP MAY
NOT BE IMMED APPARENT. CALL MD. HLTH HAZ: DELIBERATELY CONC &
INHALING CONTENTS CAN BE HARMFUL/FATAL.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:>240F,116C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.825
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CO2, CO.
Disposal
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40 CFR 261.WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE THE
APPLIC EPA HAZ WASTE NUMBERS.INCIN IN APPRVD FACILITY.DO NOT INCIN
CLSD CNTNR. DISPOS E OF I/A/W FEDERAL, STATE AND LOCAL REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.